general specifications
switching function normally closed (nc)
output type namur
rated operating distance 1.5 mm
installation flush
assured operating distance 0 ... 1.215 mm
actual operating distance 1.35 ... 1.65 mm typ.
reduction factor ral 0.3
reduction factor rcu 0.2
reduction factor r304 0.7
nominal ratings
nominal voltage 8.2 v (ri approx. 1 kω)
switching frequency 0 ... 2000 hz
hysteresis 1 ... 10 typ. 3 %
reverse polarity protection reverse polarity protected
short-circuit protection yes
suitable for 2:1 technology yes , reverse polarity protection diode not required
current consumption
measuring plate not detected min. 3 ma
measuring plate detected ≤ 1 ma
switching state indicator led, yellow
functional safety related parameters
mttfd 3590 a
mission time (tm) 20 a
diagnostic coverage (dc) 0 %
compliance with standards and directives
standard conformity
namur en 60947-5-6:2000
iec 60947-5-6:1999
approvals and certificates
fm approval
control drawing 116-0165
ul approval culus listed, general purpose
csa approval ccsaus listed, general purpose
ccc approval ccc approval / marking not required for products rated ≤36 v
ambient conditions
ambient temperature -25 ... 100 °c (-13 ... 212 °f)
storage temperature -40 ... 100 °c (-40 ... 212 °f)
mechanical specifications
connection type cable pvc , 2 m
core cross-section 0.14 mm2
housing material stainless steel 1.4305 / aisi 303
sensing face lcp
housing diameter 8 mm
degree of protection ip67
cable
bending radius > 10 x cable diameter
general information
use in the hazardous area see instruction manuals
category 1g; 2g; 3g; 1d
上海韵祉工贸有限公司
18001703796